EA890 10-120kVA (3:3)
● Online double-conversion with full DSP control
● IGBT inverter with output isolation transformer
● 100% unbalance load capability
● Output power factor 0.9
● Generator compatible
● Support battery cold start and auto-restart when mains power is restored
● ECO mode operation for energy saving
● Superior protection
● 7 inches LCD touch screen, friendly human & machine interface
● Front access makes maintenance and replacement simplified (60 ~ 120 kVA)
● Intelligent self-diagnosing function, all kinds of failure protection, large capability of history records storage
● High MTBF (> 200,000 h)
● Low MTTR (< 0.5 h)
● Standard emergency power off (EPO)
● Standard RS232, RS485, dry contacts communication port
● Optional SNMP communication port
● Optional N+X redundancy parallel up to 6 units
● Optional input filter to improve input power factor
EA660 50-1200kVA
l Dual DSP digital control technology
l Flexible modularity and easy scalability with all hot-swappable module design
l High efficiency at low load rate: 97% at 40% rated load and 96% at 20% rated load
l High power density of 100 kVA / 3U power module
l Wide input voltage range, high grid adaptability, strong load adaptability and strong overload capability
l Small footprint (600 kVA system only 0.8 m2 footprint)
l Inbuilt integrated PDU system, easy installation and saving investment
l Input power factor > 0.99, THDi < 3%, environment friendly and high-efficiency and energy-saving
l Soft-start technology improves generator matching up to 1:1.1
l Support two modes of frequency conversion: 50 Hz input / 60 Hz output and 60 Hz input / 50 Hz output
l Intelligent hibernation design enables UPS to operate efficiently at low load rate to prolong service life and improve the system efficiency.
l Advanced parallel expansion technology, support 4 units in parallel
l Share battery pack in parallel operation, saving user’s battery cost
l Flexible charger parameter and battery configuration setting, numbers of battery 30 ~ 50 pcs selectable
l Intelligent battery management (Intelligent charge/discharge management and float charging voltage temperature compensation), extending battery lifespan
l Support battery cold start and utility self boot
l Self-aging function, easy debugging and test on site
l Fault-tolerant design for fan system: 20% load can be driven when 2 fans fail and 50% load when 1 fan fails
l Front accessible maintenance, top/bottom cable entry compatible
l Complete hardware and software protection function, robust self-diagnostic function, and abundant event log for check
l 7 inches LCD touch screen, friendly human-machine interface
l Monitoring unit with built-in SNMP, supports RS485 and dry contacts